Micomme Product Non incursio Ventilator ST-30K
Descriptio
Ventilationes non incursio (NIV) refertur ad praescriptum subsidii ventilatorii per aegri airway superiorem larvam vel similem machinam utendi.
EVENTILATIO non incursio patientem sustinet, tradens inspiratoriorum et expiratoriarum pressionum vel volumina dextera ad suffragia ventilatoria singula sustinenda, alveolorum minutorum evacuationem amplificans et alveoli collapsos reficiendo.
Applicationem
Angustiae respiratoriae acuta syndrome (ARDS) insignitur ab acuto impetu respiratorii defectu, opacitatibus pulmonis diffusis et hypoxemia gravi.Usus NIV adiuvare potest ad vitandas huiusmodi complicationes sicut altioris incidentiae ventilator-associatae pneumonia et barotrauma.
Aegri cum notis vel suspectis COVID-19 cum defectu respiratorii primo intubati et ventilari debent in curriculo morborum sine optione curationum minus incursivorum, etiam invasivorum non evacuationum (NIV).
Commodum
6-gradus (100~600ms) pressionis tempore oriuntur, ut occurrant necessitates physiologicae diversarum fluunt rates, initio inspirationis.
Pressio mensuratur in latere larva.Pressio caligarum mensurandi coniungitur cum pressione prope portum in sinistra parte machinae metientis et Tee ad extremum larvae (intra fasciculum larvae) ad pressionem in larva colligendam.
Specification
Parameter | ST-30K |
VENTILATIO modus | S/T, CPAP, S, T, PC, VAT, HFNC |
Oxygen concentratio | 21%~100%, (incrementum 1%) |
Screen magnitudine | 5.7 Inch color screen |
Waveform ostentationem | Pressura / flow |
IPAP | 4~40cm H2O |
EPAP | 4~25cm H2O |
CPAP | 4~20cm H2O |
Scopum Thadal volumen | 20~2500mL |
Tergum BPM | 1~60BPM |
Tergum tempus | 0.2~4.0S |
Surge tempus | 1~6 level |
Aggerem tempus | 0~60min |
Aggerem pressura | CPAP modus: 4~20cm H2O Alius modus: 4~25cm H2O |
Pressura subsidio | 1~3 level |
Spontaneus Timin | 0.2~4.0S |
Spontaneus Timax | 0.2~4.0S |
Ego felis occasum | Auto, 1~3 level |
E-Trigger occasum | Auto, 1~3 level |
felis cincinno | Off, 0.3~1.5S |
Fluat HFNC modus | 10~70L/min |
Max fluxus | 300L/min |
Max Leak ultricies | 120L/min |
Modum pressura modum | Pressura probatio fistula in larva latus |
Alanus | Apnea|Disiunctio| Minimum minutum volumen| Minimum tidal volumen|Power off|Per altum pressura| Oxygen unavailable| Immodicus oxygeni pressus copia| Minimum oxygeni pressura copia | Minimum altilium | Pugna exhaustum |
Apnea terror rhoncus occasum | 0S, 10S, 20S, 30S |
Disiunctio terror rhoncus occasum | 0S, 15S, 60S; |
Real-time magna notitia | Praesens oxygeni concentratio|Oxygeni fons pressura|Pressura|ventilationis per min|rate respiratorii|Current ultrices|Current volumen|trigger methodus |
Aliae occasus | Screen lock|Display splendor|Flow|Pressura|Waveform|Eventus summary |
Tergum altilium | VIII horas |